The fully premixed low-nitrogen condensing steam generator uses stainless-steel finned economizers to preheat feedwater and produce high-temperature steam within one minute. With no need for a pressure vessel, it directly generates steam through surface-combustion radiant heating, achieving thermal efficiency up to 99%. The system features continuously variable output, compact size, and distributed installation capability.
Working Principle
Using continuous steam transmission technology, the unit maintains stable and uninterrupted steam supply with minimal heat loss. Fully premixed surface combustion provides strong radiant heat, enabling instant steam generation. Intelligent computer control allows easy switching between steam, hot-water supply, and heating modes.
Water-vapor separation recycles moisture to ensure saturated steam output. Stepless variable-speed heating automatically adjusts burner output based on system load, maintaining optimal efficiency.

Features
Fully premixed surface combustion thoroughly mixes air and gas before ignition, ensuring complete combustion, high efficiency, and ultra-low emissions.
Key characteristics include:
High thermal efficiency, low CO, and significantly reduced NOx.
Short, uniform flame without high-temperature zones.
Lower combustion and flue noise.
Compact chamber design due to premixed flame characteristics.
Wide modulation range (100–15000 kW/m²).
Efficient radiant heat transfer at low loads.
Low thermal inertia with fast temperature response.
Safe operation with low tempering tendency.
Advantages
No pressure vessel (water volume <30L); no annual inspection required.
Over 30% energy-saving vs. traditional gas boilers; thermal efficiency up to 100.05%.
Rapid heating; adjustable steam temperature 120–180°C.
One-button start; full intelligent control with precise temperature management.
IoT monitoring with real-time data.
304L stainless-steel condensing fins, corrosion-resistant and long service life.
Ultra-low emissions (<30 mg/m³), meeting strict environmental standards.
Ultra-compact footprint—only 1/5 of a traditional boiler; single-person movable.
Equipped with high-end FASCO fan for durability.
Certified by national authorities; no safety review required.
Infinitely adjustable output (20%–100%); stable continuous steam production.
Silent operation with minimal heat loss.
Standard pressure ≤12 Kg, customization up to 20 Kg.
Supports return water temperatures up to 120°C.
Technical parameters of fully premixed gas steam generator | |||
Itemize |
Project |
Describe |
Notes |
|
Boiler body materials and related technical parameters |
Model |
LSS1-1.25-Q |
1 ton steam |
Boiler type |
Vertical cross flow |
||
Rated evaporation |
1t/h |
||
Rated pressure |
1.25Mpa |
||
Rated thermal efficiency |
98-101% |
||
Rated gas consumption |
72.8NM3/h
|
LNG |
|
Size(mm) |
1980*1230*2200 |
Pressure switch height 200mm. |
|
Evaporator volume |
29.8L |
geometric volume |
|
Weight |
1010KG |
||
Furnace material |
3.2mm+304
Standard boiler steel 3.2mm
+ 304 fins
|
||
Weld |
Full argon arc |
||
Condenser material |
304L
304L stainless steel
|
||
Condenser circulation pipe |
DN25 |
||
Diameter of the chimney |
Φ200 |
||
water capacity |
29.8L
(No inspection and
supervision required)
|
||
burner |
Total premixed
surface combustion
|
||
Combustion machine valve assembly |
Siemens |
||
(NOx) |
<30Mg |
||
Steam outlet / Safety valve |
DN40 |
||
Gas intake pipe diameter |
DN40 |
||
Gas pressure (kinetic pressure in KPa) |
5-8 |
||
Inlet water diameter |
DN25 |
||
drain outlet |
DN25 |
Manual-automatic integration |
|
sparking mode |
Automatic electronic ignition |
||
Gross electric capacity |
5KW |
Including a water replenishment pump
and a condensation circulation pump
|
|
Note: 1. In terms of fuel consumption, the low heating value is 8500Kcal/Nm3/h for natural gas. | |||
2. Water quality requirement: conductivity less than 20us/cm. | |||
For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.